Fun with 3D Printing: Print a Parametric Peristaltic Pump

So, I’ve been playing around with the Lulzbot we got at work. Inspired by emmett’s sweet planetary gear bearing design, I adapted the design to be not a bearing but a peristaltic pump. Like the original bearing design, the pump prints as a single piece – no assembly required! – with captive rollers and no rotary bearing/wear surfaces. The only extra part needed is a length of surgical tubing to thread through the mechanism. This initial print is a proof-of-concept and is driven by a standard 1/4″(?) hex nut driver or Allen key: for a real application, you’d want to add a mount for an electric motor or similar. This one (or one like it) will probably end up attached to a small gearmotor and solar panel in my greenhouse to slowly trickle water through an aquaponics tower.

Printable Peristaltic Pump with captive rollers and minimal wear surfaces

Printable Peristaltic Pump with captive rollers and minimal wear surfaces

Pump with latex surgical tubing installed

Pump with latex surgical tubing installed

The pump design is written in OpenSCAD and pretty much fully parametric: the desired diameter, height, tubing geometry and a few other parameters can be tweaked as needed. There are a couple warts I’ll discuss later on.

Download:
You can download the OpenSCAD file here.

Video:
Here is a video of the pump in operation.

General:
Peristaltic pumps operate on the same principle as your esophagus and intestines (yes, really – yuck…) – a squishy length of hose is squeezed starting from one end and ending at the other, forcing any contents along for the ride. This type of pump has several properties that make it useful in certain applications:

  • Self-priming – can pump air or fluid reasonably well
  • Able to pump viscous, chunky or otherwise particulate-filled liquids that would gum up or damage an impeller pump
  • Gives great head – Ehhem… “head” refers to the maximum height the pump can push fluid. For a comparable energy input, a peristaltic pump can generally push fluid up much larger elevation gains than typical impeller types. Flowrate is another story of course.
  • Precise volume delivery – the amount of fluid (or air, etc.) dispensed per rotation of the motor is much more predictable than with an impeller pump. Using a servo or stepper motor, the volume pumped can be very accurately controlled. For this reason, peristaltic pumps are commonly used in medical equipment to meter out IV fluids, handle body fluids or dispense drugs.
  • Corrosion-free, isolated fluid path – Also of great relevance to medical applications, the fluid makes contact only with the tubing, making it very self-contained and minimizing the risk of contamination – e.g. all the nooks and crannies where foreign matter and bacteria could hide in other pumps. Very important when pumping bodily fluids out of someone and then back in (e.g. dialysis). Likewise, if your pump guts were metal, pumping corrosive fluids would be OK at the two never touch.

I really can’t stress the medical angle enough: in a hospital setting, peristaltic pumps are everywhere. Being able to print them off for practically free is huge.

Of course they are not without drawbacks; among them are fairly low flowrates, often “spurty” output, added friction losses and finite tubing life.

Assembly:
The pump prints out pretty much preassembled, but you still have to supply the tubing. Latex or Tygon surgical tubing is ideal, but most any pliable tubing (PVC fishpump tubing, etc.) can be used. To install, poke the tubing into one of the holes on the side of the mechanism (move the rollers if necessary so it is not blocked), pull through the desired amount of slack, then slowly advance the rollers to push the tubing up against the inner wall. When it reaches the other hole, push through and pull out any remaining slack. Note, the design is symmetric, so the concept of “inlet” and “outlet” port just depends on which direction you turn the rollers.

Design Considerations:

The diameter and wall thickness of the tubing dictate the pump geometry to some degree: the rollers and corresponding track must be wide enough to accommodate the tubing’s width when squished flat, and the clearance between the two must be enough to squeeze it flat without applying excessive force. This can be adjusted via the tubing_squish_ratio variable. The pump shown used a value of 0.5 with good results, but if you don’t need excessive pressure/head, lower values should work fine and reduce friction.

In general, a larger overall pump diameter will minimize wear on the tubing.

When using an FDM (plastic-extruding) printer, crazy overhangs in the geometry can’t be printed without support material (which defeats the purpose of a print-n-play design). The parameter allowed_overhang controls the level of overhang in the output based on what your printer can print, between 0 (no overhang whatsoever) and 1 (“infinite”, i.e. 90-degree overhang). Of course a ‘0’ setting is not very practical. 45-60 degree overhang should be OK for most FDM printers (I used a raw value of 0.75 for this one).

Warts / Future Improvements:

In the current version, the final OD will actually be slightly larger than the value you enter (specifically, by the calculated tubing squished thickness. This is a result of laziness on my part; keep this in mind or fix it if you need a very exact OD on the outer ring.

When operating at high speed, I’ve noticed the tubing sometimes has a tendency to slowly “walk” in the direction opposite of travel, being slowly pulled through the pump. A compression / baffle feature at the inlet and outlet would help prevent this by friction-locking the tubing in place. Alternately, it could probably just be fixed in place with a bit of glue.

Tim Tears It Apart: Kidde KN-COB-B Carbon Monoxide Alarm

Of course it happens this way: stuff works for you, but breaks as soon as you have guests and drives them crazy. In this case, the missus and I were out of the house having a baby and her folks were in to hold down the fort. A carbon monoxide detector had failed in the most irritating possible way, emitting a very short low-battery chirp just often enough to drive everyone batty, but intermittently enough to be very time-consuming to track down. My poor father-in-law eventually managed to find the source of the racket, and changed the batteries.

The chirping continued.

He then trashed those batteries and put in another set of fresh batteries, from a new package.

The chirping continued.

And then took the damn thing off the ceiling and removed the batteries for good.

The chirping continued.

Oh yeah, it turns out that not one, but TWO detectors had failed simultaneously. And not for want of batteries, either.

It turns out the detector elements in most modern CO detectors have an indeterminate-but-finite lifespan, and are programmed to self-destruct when their time’s up. The actual sensor lifespan depends on the usual factors like operating temperature, humidity, CO exposure, etc., but most manufacturers take the easy way out and simply define a conservative time value where it may need replacing. In this case, it is 7 years. (I bought the house about 7 years ago, hmmm…)

Self-destruct timer disclaimer on back of detector

Self-destruct timer disclaimer on back of detector

Although design-to-fail schemes are occasionally on legally shaky ground, this product-death-timer is actually required by UL for CO detector products whose detector has a limited lifespan (which is most of them).

While they still power-on and blink (it’s not clear if the timer expiration also explicitly disables CO detection, but the labeling on the back suggests so), these units are basically landfill fodder now. I think you know what that means…

Front of detector with battery door removed. The marking indicating the direction to pull to release it from the nails in the ceiling is NOT factory stock :-)

Front of detector with battery door removed. The marking indicating the direction to pull to release it from the nails in the ceiling is NOT factory stock :-)

Top side of PCB

Top side of PCB

Top side of PCB with piezo horn removed

Top side of PCB with piezo horn removed

Bottom side of PCB

Bottom side of PCB

Main parts:
CPU: PIC16LCE625 – One-time programmable 8-bit microcontroller with 2k ROM / 128 byte RAM, 128 byte EEPROM.

MCP6042I/P – Dual Low power (0.6uA) opamp – guard ring attached to pin 7

LM385-1.2 (package marking 385B12) – 1.2V voltage reference with minimum operating current of 15uA.

Noisemaker: Ningbo East Electronics EFM-290ED piezoelectric horn claiming 90dB(A) sound output @ 9V/10mA @ 30cm.
Has GND, main and feedback connection.

Ningbo East Electronics ELB-38 or ELB-74 (?) – 3-terminal inductor (autotransformer) generating a stepped-up AC voltage to drive the horn.

A scattering of bog-standard transistors (2n3904/3906) rounds out the silicon ensemble.

The detector is a large metal cylinder marked with a Kidde part number and has a silica gel (dessicant) package shrink-wrapped to the front of the detection end. The detector is soldered to the board and not replaceable.

Business end of CO sensor showing silica gel dessicant covering aperture

Business end of CO sensor showing silica gel dessicant covering aperture

Some points of interest:

Idiot resistance: One thing to notice even before taking the unit apart are the little red spring-loaded tabs underneath each battery socket. I couldn’t find anything on the purpose of these in a quick web search, but my guess is they are there to block you from putting the battery door back on with no batteries in, e.g. after pulling them to silence a chirping alarm at 3am, and then forget to put new ones in.

Horn drive: Piezo horns are resonant systems with a very high Q; they must be driven at resonance to produce anywhere near their maximum sound output. However, due to manufacturing tolerances the exact resonant frequency may differ significantly between individual units. Another issue for this device is that piezo horns need comparatively high voltages to operate: this one has a rated voltage of 9V, but can probably go a fair amount higher (>100V drive signals for larger piezo sounders are not uncommon). But, the 3x AA batteries in this device can deliver a maximum of only ~4.5V. The self-resonant oscillator formed by Q2 and L1 efficiently solves both problems. The ‘feedback’ pin connects to a small patch of piezo material on the horn that acts as a sensor, translating deflection to voltage (more or less). Using this as the control signal for a simple oscillator allows it to automatically pull in to the piezo’s resonant frequency. The autotransformer coil, L1, is basically a step-up transformer with one end of its primary and secondary windings tied together and connecting to the 2nd pin. (You can think of it as a single winding with an asymmetric center-tap if you prefer.)

Detector analog frontend: The FR4 material the PCB is made of is a pretty good insulator, but its resistance is not infinite. With sensitive high impedance signals in the tens of Megaohm or more, even the tiny leakage currents across the PCB can induce a measurement error – especially when dust, finger oils from manufacture, other residue and humidity from the air combine on the surface. Notice the exposed silver trace that completely circumscribes the PCB area occupied by the sensor, with its green soldermask covering purposely omitted. This is almost certainly a guard ring intended to intercept such PCB leakage currents before they reach the connection points of the chemical CO sensor. The trace will be attached to a low-impedance circuit node whose voltage is as close to the sensor terminal voltage as possible, minimizing the voltage difference between them, and thus the current that can leak across. The trace is tied to pin 7 of the opamp.

Closeup of guard ring trace surrounding analog frontend

Closeup of guard ring trace surrounding analog frontend

End-of-life-lockout: As mentioned previously, this device is programmed to commit suicide after 7 years. There is no battery backup inside the device, nor any discrete realtime clock or other means of telling the time. How does it know when 7 years have elapsed? The CPU is clocked by a 32.768KHz crystal oscillator, otherwise known just as a “watch crystal” due to their ubiquitous use in watches, clocks and other timekeeping applications. While running the CPU at such a low speed also has certain power advantages relevant to a battery-powered system, this crystal is providing an accurate timebase. Needless to say, it is counting 7 years of power-on time, not wall time (even if it sat on the shelf quite a while, your alarm will not be dead and chirping the moment you remove it from the package). The CPU sports 128 bytes of EEPROM, which are used to store the peak CO reading (over the product’s lifetime or since the last alarm; not sure which) and most likely periodically count down its remaining lifetime. Basic operation of a CO detector is to stick batteries in and forget about it (unexpected powercycles will be infrequent), so the timekeeping can be very coarse, e.g. decrementing a couple-byte EEPROM countdown every time a very long counter rolls over some preprogrammed value.

I pulled the CPU, hooked it up to an ancient PIC programmer and tried dumping the firmware to see exactly how this worked, just in case they had left it unprotected, but no such luck. The code protect fuses are all set and readout attempts return all 0s. The EEPROM in this particular chip is actually implemented as a separate I2C “part”, either on the same die or a separate die copackaged with the CPU die, with the two I2C control pins and a power control line memory-mapped into a register. So there is no access to the EEPROM contents through a PIC programmer either.

Enclosure: At first glance, it’s about what you expect from a low cost consumer product that is designed to be thrown away periodically. There is not a screw to be found anywhere – everything, from the PCB to the enclosure halves themselves, clicks together via little plastic tabs. But wait a minute… hold this up to the light just right, and you can see hand-finishing marks where extra plastic (e.g. overmold) from the injection molding process has been filed or sanded off. On the *inside* of the enclosure, where nobody will see it! And yes, these marks appear to be from work applied to the finished enclosure itself, not the master mold it came from – the sanded portions go slightly in, not out.

Manual finishing marks on inside of plastic enclosure

Manual finishing marks on inside of plastic enclosure

Hidden Features: There are a few hidden features suggesting this same PCB, CPU and firmware are used for several models of alarm, including a fancier one. The most obvious is a non-stuffed footprint for another pushbutton switch, marked ‘PEAK’. When pressed, it causes the green test LED to flash a number of times in a row (presumably corresponding to the peak CO level ever measured by this detector – my 2 dead units show 9 and 10 blinks, respectively). Near the center of the board is a non-stuffed 6-pin header, with the outer two being power & ground, and the middle four signals going straight to CPU pins. Scoping these reveals unidirectional SPI signalling on 3 of the pins (CS\, CLK, DATA) that would probably drive an LCD readout on a more expensive version of this detector. Capturing the data in various modes doesn’t produce any obvious pattern (e.g. ASCII, numeric, BCD or raw 7-segment data). Finally, there are two mystery pads on the back of the PCB. Shorting them causes both the alarm and test LEDs to light, and the green LED to produce 5 extremely rapid blinks every few seconds. Doing this does not reset the timer-of-death, clear the PEAK reading or have any other long-term effects that I can ascertain. Both the PEAK switch and mystery jumper noticeably change the data pattern sent to the nonexistent LCD.

BUT… I did find a sequence of inputs that put the detector into some kind of trick mode permanently (persisting across powercycles). I believe the exact sequence of events that triggered it was to have S2 shorted at powerup, then short PEAK once the blinking sequence starts. It’s not clear if S2 must remain shorted during this time or only at powerup. The unit this sequence occurred on is now permanently in a mode where it emits long, repeating rapid blink sequences on the green LED (red lit continuously) and draws some 40mA continuously. The repeating sequence is 1 (pause) 63 (pause) 68 (pause) 24 (pause) 10 (last blink is longer) (pause) 21 (pause) 82 (pause) 82 (pause) 14 (long pause).

It’s official – I have spawn!

So…
That day I never thought would come, and a younger me once *hoped* would never come…has come!

Our first spawn, Max Charles G, was born 7/26/2014 at around 6:40am.

Glad that’s over!

I kid, but seriously, the hospital part is the only real sucky part (for us, at least – Max is pretty chill). The part where you’ve both already been awake for a day and a half, the Mrs. is just all sorts of tore up, and the Mr. is camped out on this “thing” pretending to be a chair pretending to be a fold-out bed and failing outright at both. In otherwords, a medieval sleep-deprivation torture experiment of some kind. And then comes this tiny human that starts a one-sided screaming match every couple hours while you newbs haven’t more than a few books and a Google’s worth of a clue what to do about it. And about the second or third day of this you lay there with the tiny human in your arm, rubbing your eyes, thinking: Oh shit. This is what our lives will be now.

(Sometime on day 2-or-something of hospital)
T: I don’t even know what day this is.
K: It’s Monday.
T: It FEELS like a monday.
K: Get ready, every day’s going to feel like a Monday.

But… then you go home, sleep in your own bed, start getting the hang of all this feeding and changing business, and find out: those first several days are a fluke, and hey, this ain’t so bad after all! In fact, much like marriage for a dude, either I won the wife/baby lottery or the hype is BS: this is turning out to be much better than I expected.

Ah yes, and the tiny human is growing on me. I wasn’t expecting that either.